Internal Twin Wall Assembly Guide
Basic Internal Installation
The chimney should be appropriately supported at 4m intervals, with lateral support every 1.5m. Refer to the manufacturer's instructions for more details.
Joints within walls, ceilings, or floors should NOT be made.
Where there is a risk of combustible materials coming into contact with the system, the minimum distance from combustible materials (60mm) must be maintained throughout by a permanent enclosure or shield.
When the system goes through a wall, a sleeve should be used and weather-proofed as required.
Components should not be modified.
A chimney notice plate, carbon monoxide detector, and air vent should be installed in the same room as the appliance.

Please Note: Flue Finder does not know the exact situation or circumstances of your home and/or the quality of the products already in place. Although the advice and quotation provided will be based on the details submitted by you, any person who relies upon any advice provided by Flue Finder—whether by email, phone, or from content on the Flue Finder website—does so at their own risk. Flue Finder therefore accepts no duty or liability whatsoever, other than the duty to act honestly and in good faith.